The SunLink hybrid inverter is the brain of your home energy system. It does more than convert solar into usable power - it intelligently manages energy flow between grid, battery and household loads. While the grid is healthy, solar comes first; during outages it switches seamlessly to battery backup. Our inverters support multiple battery types and offer remote monitoring, making energy management simple and intuitive.
Switches to backup power within milliseconds when the grid goes down, keeping critical loads online
Automatically optimizes energy flow between solar, battery and grid to lower your electricity bill.
Compatible with mainstream lithium and lead-acid batteries for flexible system design.
Track real-time status from a mobile app and stay on top of your energy usage anywhere, anytime.
Advanced MPPT technology maximizes solar harvesting efficiency.
Model | KE-15KD5H3EN | KE-20KD5H3EN | KE-25KD5H3EN | KE-29K9D5H3EN | KE-30KD5H3EN | KE-30KD5H3EN | KE-35KD5H3EN | KE-40KD5H3EN | KE-50KD5H3EN | KE-60KD5H3EN | ||||
PVInput Data | ||||||||||||||
Max Connected PV Power (W) | 30000 | 40000 | 50000 | 59800 | 60000 | 30000 | 35000 | 40000 | 50000 | 60000 | ||||
Max PV Input Voltage(V) | 1000 | 1000 | ||||||||||||
Startup Voltage(V) | 180 | 180 | ||||||||||||
MPPTVoltage Range(V) | 150-850 | 150-850 | ||||||||||||
RatedPVInput Voltage(V) | 600 | 600 | ||||||||||||
Max Operating PV Input Current(A) | 40 | 40 | ||||||||||||
Max Input Short-Circuit Current(A) | 65 | 65 | ||||||||||||
MPPTNumber of Trackers | 3 | 4 | ||||||||||||
Max Number of Input Strings | 02/2/2 | 02/2/2 | ||||||||||||
Battery Parameters | ||||||||||||||
Battery Type | LFP Battery | LFP Battery | ||||||||||||
Rated Battery Voltage(V) | 150~800 | 150~800 | ||||||||||||
Max Charge/Discharge Current(A) | 70*2 | 70*2 | ||||||||||||
AC Output Data | ||||||||||||||
Rated AC Output Active Power(W) | 15000 20000 25000 29900 30000 | 30000 | 35000 | 40000 | 50000 | 60000 | ||||||||
AC Output Apparent Power(VA) | 16500 22000 27500 32890 33000 | 33000 | 38500 | 44000 | 55000 | 66000 | ||||||||
Rated AC Output Current(A) | 22.7 30.3 37.88 45.3 45.5 | 45.5 | 53 | 60.6 | 75.8 | 90.9 | ||||||||
Max AC Output Current(A) | 25 33.3 41.7 49.8 50 | 50 | 58.3 | 66.7 | 83.3 | 100 | ||||||||
Rated Output Voltage(V) | 220/380; 230/400; 3L/N/PE | 220/380;230/400;3L/N/PE | ||||||||||||
Rated Input/Grid Output Frequency/Range(Hz) | 50/60,+/-5 | 50/60,+/-5 | ||||||||||||
Power Factor Adjustment Range | 1(-0.8~0.8) | 1(-0.8~0.8) | ||||||||||||
AC Input Data | ||||||||||||||
Rated AC Input Current(A) | 45.5 | 60.6 | 75.8 | 90.6 | 90.9 | 106 | 121.2 | 151.6 | 181.8 | |||||
Rated Input Voltage(V) | 220/380;230/400; 33L/N/PE | 220/380;230/400; 33L/N/PE | ||||||||||||
Off-gridOutput Parameters | ||||||||||||||
Rated Output Power(W) | 15000 | 20000 | 25000 | 29900 | 30000 | 15000 | 20000 | 25000 | 29900 | 30000 | ||||
Max Output Power(W) | of Rated Power1.6× continuous10s | of Rated Power1.5× continuous10s | ||||||||||||
Rated Output Current(A) | 22.7 | 30.3 | 41.7 | 45.3 | 45.5 | 45.5 | 53 | 60.6 | 75.8 | 90.9 | ||||
Rated Input/Grid Output Frequency/Range(Hz) | 50/60,+/-5 | 50/60,+/-5 | ||||||||||||
Power Factor Adjustment Range | 1(-0.8~0.8) | 1(-0.8~0.8) | ||||||||||||
Parallel Operation | Supported, up to10 units | Up to10 units | ||||||||||||
Switching Time(ms) | <10 | <10 | ||||||||||||
Total Voltage THD(THDV)[%](Linear Load) | <3%(At Rated Power) | <3%(At Rated Power) | ||||||||||||
Efficiency | ||||||||||||||
Max Efficiency | 97.8% | 97.8% | ||||||||||||
European Efficiency | 97% | 97% | ||||||||||||
MPPTEfficiency | 99% | 99% | ||||||||||||
Max Efficiency(Battery toAC) | 97.6% | 97.6% | ||||||||||||
Max Efficiency(PVto Battery) | 98.1% | 98.1% | ||||||||||||
Size ( m m ) | 580×530×270 | 580x530×270 | ||||||||||||
Protection | ||||||||||||||
DC/Battery Reverse Polarity Protection | Integration | Integration | ||||||||||||
Insulation Impedance Monitoring | Integration | Integration | ||||||||||||
DC/AC Surge Protection | Integration | Integration | ||||||||||||
AC Overcurrent/Short-Circuit Protection | Integration | Integration | ||||||||||||
Ground Fault Monitoring | Integration | Integration | ||||||||||||
Grid Monitoring | Integration | Integration | ||||||||||||
String Monitoring | Integration | Integration | ||||||||||||
Anti-Islanding Protection | Integration | Integration | ||||||||||||
DC/AC Overvoltage | OVCII(DC),OVCII(AC) | OVCII(DC),OVCIII(AC) | ||||||||||||
AFCI | Optional | Optional | ||||||||||||
Ingress Protection (IP) Rating | IP66 | IP66 | ||||||||||||